Restoring a Leak-free D11 Main Stop Control Valve

After years of recurring steam leakage from the main stop control valve (MSCV), the team identified an uneven casing sealing surface and delivered an in-situ machining repair that restored a reliable, leak-free seal.

The Challenge

Over several years, the D11 steam turbine’s MSCV repeatedly leaked steam from the stop-valve stem section following planned valve inspections. Re-torquing the pressure-seal head clamp-nut bolts would stop the leakage temporarily, but the problem returned after only a short period.
The recurring leak indicated that tightening alone was not addressing the underlying sealing condition. A durable repair required disassembly and a detailed assessment of the pressure-seal head, gasket, and casing mating surfaces.

The Results

The MSCV was disassembled, revealing a deformed pressure-seal head metal gasket that had broken into multiple pieces. Contact checks on the pressure-seal head and casing mating surfaces showed that the casing sealing surface in the seating area was uneven, with minimal contact and poor flatness.
Using an on-site machining vendor, the team machined the casing sealing surface in situ, removing only 0.035 inches to restore flatness relative to the casing’s machined surfaces. Contact checks were repeated after machining. The valve was then reassembled, the stop-valve stroke was adjusted to compensate for the material removed, and all fasteners were torqued to OEM specifications. The completed repair produced a reliable, leak-free valve.

Project information

Location

United Kingdom

Market segment

Power generation

Equipment type

Steam turbine

Equipment model

D11

Restoring a Leak-free D11 Main Stop Control Valve

Location

United Kingdom

Market segment

Power generation

Equipment type

Steam turbine

Equipment model

D11

After years of recurring steam leakage from the main stop control valve (MSCV), the team identified an uneven casing sealing surface and delivered an in-situ machining repair that restored a reliable, leak-free seal.

The Challenge

Over several years, the D11 steam turbine’s MSCV repeatedly leaked steam from the stop-valve stem section following planned valve inspections. Re-torquing the pressure-seal head clamp-nut bolts would stop the leakage temporarily, but the problem returned after only a short period.
The recurring leak indicated that tightening alone was not addressing the underlying sealing condition. A durable repair required disassembly and a detailed assessment of the pressure-seal head, gasket, and casing mating surfaces.

The Results

The MSCV was disassembled, revealing a deformed pressure-seal head metal gasket that had broken into multiple pieces. Contact checks on the pressure-seal head and casing mating surfaces showed that the casing sealing surface in the seating area was uneven, with minimal contact and poor flatness.
Using an on-site machining vendor, the team machined the casing sealing surface in situ, removing only 0.035 inches to restore flatness relative to the casing’s machined surfaces. Contact checks were repeated after machining. The valve was then reassembled, the stop-valve stroke was adjusted to compensate for the material removed, and all fasteners were torqued to OEM specifications. The completed repair produced a reliable, leak-free valve.

0.035 in

Minimal material removed

In situ

On-site surface machining

Leak-free

Reliable valve operation restored